The 5-valve manifold consists of one shut-off valve and one vent valve per pressure side and one pressure compensating valve. The shut-off valves separate the process from the differential pressure measuring instrument. The vent valves allows operators the targeted venting of one or both pressure sides of the measuring arrangement. The pressure compensating valve enables the compensation between + side and – side to avoid one-sided overpressure during commissioning and operation.
Type IV504
Valve position Angled
Pressure compensating valve in front
Vent connection G1/8 female without plug
Center distance gauge side 37 mm
For 732.51 differential pressure gauge
For DPGS43 differential pressure gauge with switch contacts For DPGT43 differential pressure gauge with output signal
Material body stainless steel 316L
Material packing PTFE
Nominal pressure 6000 psi / 420 bar
With bracket holes for mounting with bracket
NACE Sour Gas Service
Inspection certificate 3.1 EN 10204
all wetted parts material
■ 5-valve manifold
■ Centre distance on instrument side: 37 mm [1.46 in]
■ Angled bonnet position